✓ Double Conversion
Efficiency up to 95%
✓ Transformer-Free UPS
✓ Reduced Cost
The new XRT-3PH UPS System from UPS Solutions is a transformer-free UPS which brings exceptional features for mission-critical applications. Its extraordinary double conversion efficiency up to 95% ensures remarkable operational cost savings, reducing both the Total Cost of Ownership (TCO) and the environmental impact. The XRT-3PH is the perfect power solution for both IT installations and other mission critical applications, such as transportation, emergency lighting, healthcare, retail and government facilities.
UPS Solutions can provide experienced technicians. Services include but not limited to:
- Pre-site survey
- Planning and Project Management
- Unpacking and Assembly Service
- Electrical installation and wiring
(Pricing varies based on UPS location and environment, speak to one of our consultants today to arrange
an installation service).
This service provides an experienced UPS electrician to verify proper wiring of the system, energise the
hardware, and provide the customer with basic operator training on the system started up if requested.
General | 10kVA/9kw | 20kVA/18kW | 30kVA/27kW | 40kVA/36kW |
---|---|---|---|---|
Power | three phase | three phase | three phase | three Phase |
energy saving technology | online eco mode efficiency up to 98% | ONLINE ECO MODE EFFICIENCY UP TO 98% | ONLINE ECO MODE EFFICIENCY UP TO 98% | ONLINE ECO MODE EFFICIENCY UP TO 98% |
normal mode efficiency (%) | 95% | 95% | 95% | 96% |
battery MODE EFFICIENCY (%) | 95% | 95% | 95% | 96% |
parallel expansion (max. units) | 4 | 4 | 4 | 4 |
input | ||||
dual power inputs | Yes | yes | yes | yes |
nominal input voltage (vac) | Line to neutral (l-n): 220, 230, 240 vac, line to line (l-L): 380, 400, 415 vac | LINE TO NEUTRAL (L-N): 220, 230, 240 VAC, LINE TO LINE (L-L): 380, 400, 415 VAC | LINE TO NEUTRAL (L-N): 220, 230, 240 VAC, LINE TO LINE (L-L): 380, 400, 415 VAC | LINE TO NEUTRAL (L-N): 220, 230, 240 VAC, LINE TO LINE (L-L): 380, 400, 415 VAC |
input voltage range (vac) | LINE TO NEUTRAL (L-N): 132 ~ 276 vac, LINE TO LINE (L-L): 228 ~ 478 VAC | LINE TO NEUTRAL (L-N): 132 ~ 276 VAC, LINE TO LINE (L-L): 228 ~ 478 VAC | LINE TO NEUTRAL (L-N): 132 ~ 276 VAC, LINE TO LINE (L-L): 228 ~ 478 VAC | LINE TO NEUTRAL (L-N): 132 ~ 276 VAC, LINE TO LINE (L-L): 228 ~ 478 VAC |
INPUT frequency (hz) | 50 ± 3, 60 ± 3 | 50 ± 3, 60 ± 3 | 50 ± 3, 60 ± 3 | 50 ± 3, 60 ± 3 |
INPUT FREQUENCY range (HZ) | 40 ~ 70 | 40 ~ 70 | 40 ~ 70 | 40 ~ 70 |
input power factor | 0.99 | 0.99 | 0.99 | 0.99 |
output | ||||
capacity (va) | 10000 | 20000 | 30000 | 40000 |
capacity (watts) | 9000 | 18000 | 27000 | 36000 |
rated output voltage (vac) | line to netural (l-N): 220, 230, 240 vac, line to line (l-L): 380, 400, 415 vac | LINE TO NETURAL (L-N): 220, 230, 240 VAC, LINE TO LINE (L-L): 380, 400, 415 VAC | LINE TO NETURAL (L-N): 220, 230, 240 VAC, LINE TO LINE (L-L): 380, 400, 415 VAC | LINE TO NETURAL (L-N): 220, 230, 240 VAC, LINE TO LINE (L-L): 380, 400, 415 VAC |
output voltage tolerance (%) | 1% | 1% | 1% | 1% |
output frequency (hz ± %) | 50 ± 0.1, 60 ± 0.1 | 50 ± 0.1, 60 ± 0.1 | 50 ± 0.1, 60 ± 0.1 | 50 ± 0.1, 60 ± 0.1 |
power factor | 0.9 | 0.9 | 0.9 | 0.9 |
overload protection (line mode) | 105~110% Load for 60 min, 110~125% Load for 10 min, 125~150% Load for 1 min, >150% Load Immediately | 105~110% LOAD FOR 60 MIN, 110~125% LOAD FOR 10 MIN, 125~150% LOAD FOR 1 MIN, >150% LOAD IMMEDIATELY | 105~110% LOAD FOR 60 MIN, 110~125% LOAD FOR 10 MIN, 125~150% LOAD FOR 1 MIN, >150% LOAD IMMEDIATELY | 105~110% LOAD FOR 60 MIN, 110~125% LOAD FOR 10 MIN, 125~150% LOAD FOR 1 MIN, >150% LOAD IMMEDIATELY |
crest factor | 3:1 | 3:1 | 3:1 | 3:1 |
harmonic distortion (linear load) | THD<1% | THD<1% | THD<1% | THD<1% |
HARMONIC DISTORTION (non-LINEAR LOAD) | THD<5.5% | THD<5.5% | THD<5.5% | THD<5.5% |
BAttery | ||||
battery type | vrla | VRLA | VRLA | VRLA |
Battery design life | 8 years | 8 YEARS | 8 YEARS | 8 YEARS |
Internal batteries | YES | YES | YES | YES |
external battery cabinet (optional) | YES | YES | YES | YES |
Battery quantity | 40 x 12v | 40 X 12V | 40 X 12V | 40 X 12V |
Battery monitoring system | optional | optional | optional | optional |
environmental monitoring & setup (temperature, smoke, gas & water leak detection) | OPTIONAL | OPTIONAL | OPTIONAL | OPTIONAL |
management & communications | ||||
lcd panel | yes | YES | YES | YES |
dry contact (with relay) | YES | YES | YES | YES |
EMERGENCY POWER off (epo) | YES | YES | YES | YES |
power management software | YES | YES | YES | YES |
serial port | RS232 x 1 + RS485 x 1 + Dry Contact x1 | RS232 X 1 + RS485 X 1 + DRY CONTACT X1 | RS232 X 1 + RS485 X 1 + DRY CONTACT X1 | RS232 X 1 + RS485 X 1 + DRY CONTACT X1 |
snmp/http remote monitoring | included | INCLUDED | INCLUDED | INCLUDED |
dimensions | ||||
Dimensions (WXHXD IN MM) | 250 X 530 X 660 | 250 X 770 X 680 | 250 X 770 X 680 | 250 X 770 X 836 |
wedight (kg) | 31 | 50 | 50 | 61 |
environmental | ||||
operating temperature | 0 ~ 40 | 0 ~ 40 | 0 ~ 40 | 0 ~ 40 |
OPERATING RELATIVE HUMIDITY (NON-CONDENSING) (%) | 0 ~ 95 | 0 ~ 95 | 0 ~ 95 | 0 ~ 95 |
storage RELATIVE HUMIDITY (NON-CONDENSING) (%) | 0 ~ 95 | 0 ~ 95 | 0 ~ 95 | 0 ~ 95 |
storage temperature (°C) | -40 ~ 70 | -40 ~ 70 | -40 ~ 70 | -40 ~ 70 |
audible noise at 1m from surface of unit (db) | 58 | 58 | 58 | 58 |
warranty & services | ||||
standard warranty | 2 year for electronics - 1 year for batteries | 2 YEAR FOR ELECTRONICS - 1 YEAR FOR BATTERIES | 2 YEAR FOR ELECTRONICS - 1 YEAR FOR BATTERIES | 2 YEAR FOR ELECTRONICS - 1 YEAR FOR BATTERIES |
extended warranty available | yes | YES | YES | YES |
start-up commissioning service 5x8 | included | included | included | included |
START-UP COMMISSIONING SERVICE 7X24 | optional | optional | optional | optional |
battery monitoring system | optional | optional | optional | optional |
environmental monitoring & setup (temperature, smoke, gas & water leak detection) | optional | optional | optional | optional |
certifications | ||||
certifications | CE, IEC62040-1, IEC62040-2 | CE, IEC62040-1, IEC62040-2 | CE, IEC62040-1, IEC62040-2 | CE, IEC62040-1, IEC62040-2 |
General | 10kVA/9kw | 20kVA/18kW | 30kVA/27kW | 40kVA/36kW |
---|---|---|---|---|
Power | three phase | three phase | three phase | three Phase |
energy saving technology | online eco mode efficiency up to 98% | ONLINE ECO MODE EFFICIENCY UP TO 98% | ONLINE ECO MODE EFFICIENCY UP TO 98% | ONLINE ECO MODE EFFICIENCY UP TO 98% |
normal mode efficiency (%) | 95% | 95% | 95% | 96% |
battery MODE EFFICIENCY (%) | 95% | 95% | 95% | 96% |
parallel expansion (max. units) | 4 | 4 | 4 | 4 |
input | ||||
dual power inputs | Yes | yes | yes | yes |
nominal input voltage (vac) | Line to neutral (l-n): 220, 230, 240 vac, line to line (l-L): 380, 400, 415 vac | LINE TO NEUTRAL (L-N): 220, 230, 240 VAC, LINE TO LINE (L-L): 380, 400, 415 VAC | LINE TO NEUTRAL (L-N): 220, 230, 240 VAC, LINE TO LINE (L-L): 380, 400, 415 VAC | LINE TO NEUTRAL (L-N): 220, 230, 240 VAC, LINE TO LINE (L-L): 380, 400, 415 VAC |
input voltage range (vac) | LINE TO NEUTRAL (L-N): 132 ~ 276 vac, LINE TO LINE (L-L): 228 ~ 478 VAC | LINE TO NEUTRAL (L-N): 132 ~ 276 VAC, LINE TO LINE (L-L): 228 ~ 478 VAC | LINE TO NEUTRAL (L-N): 132 ~ 276 VAC, LINE TO LINE (L-L): 228 ~ 478 VAC | LINE TO NEUTRAL (L-N): 132 ~ 276 VAC, LINE TO LINE (L-L): 228 ~ 478 VAC |
INPUT frequency (hz) | 50 ± 3, 60 ± 3 | 50 ± 3, 60 ± 3 | 50 ± 3, 60 ± 3 | 50 ± 3, 60 ± 3 |
INPUT FREQUENCY range (HZ) | 40 ~ 70 | 40 ~ 70 | 40 ~ 70 | 40 ~ 70 |
input power factor | 0.99 | 0.99 | 0.99 | 0.99 |
output | ||||
capacity (va) | 10000 | 20000 | 30000 | 40000 |
capacity (watts) | 9000 | 18000 | 27000 | 36000 |
rated output voltage (vac) | line to netural (l-N): 220, 230, 240 vac, line to line (l-L): 380, 400, 415 vac | LINE TO NETURAL (L-N): 220, 230, 240 VAC, LINE TO LINE (L-L): 380, 400, 415 VAC | LINE TO NETURAL (L-N): 220, 230, 240 VAC, LINE TO LINE (L-L): 380, 400, 415 VAC | LINE TO NETURAL (L-N): 220, 230, 240 VAC, LINE TO LINE (L-L): 380, 400, 415 VAC |
output voltage tolerance (%) | 1% | 1% | 1% | 1% |
output frequency (hz ± %) | 50 ± 0.1, 60 ± 0.1 | 50 ± 0.1, 60 ± 0.1 | 50 ± 0.1, 60 ± 0.1 | 50 ± 0.1, 60 ± 0.1 |
power factor | 0.9 | 0.9 | 0.9 | 0.9 |
overload protection (line mode) | 105~110% Load for 60 min, 110~125% Load for 10 min, 125~150% Load for 1 min, >150% Load Immediately | 105~110% LOAD FOR 60 MIN, 110~125% LOAD FOR 10 MIN, 125~150% LOAD FOR 1 MIN, >150% LOAD IMMEDIATELY | 105~110% LOAD FOR 60 MIN, 110~125% LOAD FOR 10 MIN, 125~150% LOAD FOR 1 MIN, >150% LOAD IMMEDIATELY | 105~110% LOAD FOR 60 MIN, 110~125% LOAD FOR 10 MIN, 125~150% LOAD FOR 1 MIN, >150% LOAD IMMEDIATELY |
crest factor | 3:1 | 3:1 | 3:1 | 3:1 |
harmonic distortion (linear load) | THD<1% | THD<1% | THD<1% | THD<1% |
HARMONIC DISTORTION (non-LINEAR LOAD) | THD<5.5% | THD<5.5% | THD<5.5% | THD<5.5% |
BAttery | ||||
battery type | vrla | VRLA | VRLA | VRLA |
Battery design life | 8 Year Design with UPS Solutions External Battery Cabinet | 8 YEAR DESIGN WITH UPS SOLUTIONS EXTERNAL BATTERY CABINET | 8 YEAR DESIGN WITH UPS SOLUTIONS EXTERNAL BATTERY CABINET | 8 YEAR DESIGN WITH UPS SOLUTIONS EXTERNAL BATTERY CABINET |
Internal batteries | NO | NO | NO | NO |
external battery cabinet (optional) | YES | YES | YES | YES |
Battery quantity | Configured by UPS Solutions as per required battery runtime | CONFIGURED BY UPS SOLUTIONS AS PER REQUIRED BATTERY RUNTIME | CONFIGURED BY UPS SOLUTIONS AS PER REQUIRED BATTERY RUNTIME | CONFIGURED BY UPS SOLUTIONS AS PER REQUIRED BATTERY RUNTIME |
Battery monitoring system | optional | optional | optional | optional |
environmental monitoring & setup (temperature, smoke, gas & water leak detection) | OPTIONAL | OPTIONAL | OPTIONAL | OPTIONAL |
management & communications | ||||
lcd panel | yes | YES | YES | YES |
dry contact (with relay) | YES | YES | YES | YES |
EMERGENCY POWER off (epo) | YES | YES | YES | YES |
power management software | YES | YES | YES | YES |
serial port | RS232 x 1 + RS485 x 1 + Dry Contact x1 | RS232 X 1 + RS485 X 1 + DRY CONTACT X1 | RS232 X 1 + RS485 X 1 + DRY CONTACT X1 | RS232 X 1 + RS485 X 1 + DRY CONTACT X1 |
snmp/http remote monitoring | included | INCLUDED | INCLUDED | INCLUDED |
dimensions | ||||
Dimensions (WXHXD IN MM) | 250 X 530 X 660 | 250 X 770 X 680 | 250 X 770 X 680 | 250 X 770 X 836 |
wedight (kg) | 31 | 50 | 50 | 61 |
environmental | ||||
operating temperature | 0 ~ 40 | 0 ~ 40 | 0 ~ 40 | 0 ~ 40 |
OPERATING RELATIVE HUMIDITY (NON-CONDENSING) (%) | 0 ~ 95 | 0 ~ 95 | 0 ~ 95 | 0 ~ 95 |
storage RELATIVE HUMIDITY (NON-CONDENSING) (%) | 0 ~ 95 | 0 ~ 95 | 0 ~ 95 | 0 ~ 95 |
storage temperature (°C) | -40 ~ 70 | -40 ~ 70 | -40 ~ 70 | -40 ~ 70 |
audible noise at 1m from surface of unit (db) | 58 | 58 | 58 | 58 |
warranty & services | ||||
standard warranty | 2 year for electronics - 1 year for batteries | 2 YEAR FOR ELECTRONICS - 1 YEAR FOR BATTERIES | 2 YEAR FOR ELECTRONICS - 1 YEAR FOR BATTERIES | 2 YEAR FOR ELECTRONICS - 1 YEAR FOR BATTERIES |
extended warranty available | yes | YES | YES | YES |
start-up commissioning service 5x8 | included | included | included | included |
START-UP COMMISSIONING SERVICE 7X24 | optional | optional | optional | optional |
battery monitoring system | optional | optional | optional | optional |
environmental monitoring & setup (temperature, smoke, gas & water leak detection) | optional | optional | optional | optional |
certifications | ||||
certifications | CE, IEC62040-1, IEC62040-2 | CE, IEC62040-1, IEC62040-2 | CE, IEC62040-1, IEC62040-2 | CE, IEC62040-1, IEC62040-2 |
General | 60kVA/54kw | 80kVA/72kW | 90kVA/81kW | 100KVA/90KW |
---|---|---|---|---|
Power | three phase | three phase | three phase | three Phase |
energy saving technology | online eco mode efficiency up to 98% | ONLINE ECO MODE EFFICIENCY UP TO 98% | ONLINE ECO MODE EFFICIENCY UP TO 98% | ONLINE ECO MODE EFFICIENCY UP TO 98% |
normal mode efficiency (%) | 95% | 95% | 95% | 96% |
battery MODE EFFICIENCY (%) | 95% | 95% | 95% | 96% |
parallel expansion (max. units) | 4 | 4 | 4 | 4 |
input | ||||
dual power inputs | Yes | yes | yes | yes |
nominal input voltage (vac) | Line to neutral (l-n): 220, 230, 240 vac, line to line (l-L): 380, 400, 415 vac | LINE TO NEUTRAL (L-N): 220, 230, 240 VAC, LINE TO LINE (L-L): 380, 400, 415 VAC | LINE TO NEUTRAL (L-N): 220, 230, 240 VAC, LINE TO LINE (L-L): 380, 400, 415 VAC | LINE TO NEUTRAL (L-N): 220, 230, 240 VAC, LINE TO LINE (L-L): 380, 400, 415 VAC |
input voltage range (vac) | LINE TO NEUTRAL (L-N): 132 ~ 276 vac, LINE TO LINE (L-L): 228 ~ 478 VAC | LINE TO NEUTRAL (L-N): 132 ~ 276 VAC, LINE TO LINE (L-L): 228 ~ 478 VAC | LINE TO NEUTRAL (L-N): 132 ~ 276 VAC, LINE TO LINE (L-L): 228 ~ 478 VAC | LINE TO NEUTRAL (L-N): 132 ~ 276 VAC, LINE TO LINE (L-L): 228 ~ 478 VAC |
INPUT frequency (hz) | 50 ± 3, 60 ± 3 | 50 ± 3, 60 ± 3 | 50 ± 3, 60 ± 3 | 50 ± 3, 60 ± 3 |
INPUT FREQUENCY range (HZ) | 40 ~ 70 | 40 ~ 70 | 40 ~ 70 | 40 ~ 70 |
input power factor | 0.99 | 0.99 | 0.99 | 0.99 |
output | ||||
capacity (va) | 60000 | 80000 | 90000 | 100000 |
capacity (watts) | 54000 | 72000 | 81000 | 90000 |
rated output voltage (vac) | line to netural (l-N): 220, 230, 240 vac, line to line (l-L): 380, 400, 415 vac | LINE TO NETURAL (L-N): 220, 230, 240 VAC, LINE TO LINE (L-L): 380, 400, 415 VAC | LINE TO NETURAL (L-N): 220, 230, 240 VAC, LINE TO LINE (L-L): 380, 400, 415 VAC | LINE TO NETURAL (L-N): 220, 230, 240 VAC, LINE TO LINE (L-L): 380, 400, 415 VAC |
output voltage tolerance (%) | 1% | 1% | 1% | 1% |
output frequency (hz ± %) | 50 ± 0.1, 60 ± 0.1 | 50 ± 0.1, 60 ± 0.1 | 50 ± 0.1, 60 ± 0.1 | 50 ± 0.1, 60 ± 0.1 |
power factor | 0.9 | 0.9 | 0.9 | 0.9 |
overload protection (line mode) | 105~110% Load for 60 min, 110~125% Load for 10 min, 125~150% Load for 1 min, >150% Load Immediately | 105~110% LOAD FOR 60 MIN, 110~125% LOAD FOR 10 MIN, 125~150% LOAD FOR 1 MIN, >150% LOAD IMMEDIATELY | 105~110% LOAD FOR 60 MIN, 110~125% LOAD FOR 10 MIN, 125~150% LOAD FOR 1 MIN, >150% LOAD IMMEDIATELY | 105~110% LOAD FOR 60 MIN, 110~125% LOAD FOR 10 MIN, 125~150% LOAD FOR 1 MIN, >150% LOAD IMMEDIATELY |
crest factor | 3:1 | 3:1 | 3:1 | 3:1 |
harmonic distortion (linear load) | THD<1% | THD<1% | THD<1% | THD<1% |
HARMONIC DISTORTION (non-LINEAR LOAD) | THD<5.5% | THD<5.5% | THD<5.5% | THD<5.5% |
BAttery | ||||
battery type | vrla | VRLA | VRLA | VRLA |
Battery design life | 8 Year Design with UPS Solutions External Battery Cabinet | 8 YEAR DESIGN WITH UPS SOLUTIONS EXTERNAL BATTERY CABINET | 8 YEAR DESIGN WITH UPS SOLUTIONS EXTERNAL BATTERY CABINET | 8 YEAR DESIGN WITH UPS SOLUTIONS EXTERNAL BATTERY CABINET |
Internal batteries | NO | NO | NO | NO |
external battery cabinet (optional) | YES | YES | YES | YES |
Battery quantity | Configured by UPS Solutions as per required battery runtime | CONFIGURED BY UPS SOLUTIONS AS PER REQUIRED BATTERY RUNTIME | CONFIGURED BY UPS SOLUTIONS AS PER REQUIRED BATTERY RUNTIME | CONFIGURED BY UPS SOLUTIONS AS PER REQUIRED BATTERY RUNTIME |
Battery monitoring system | optional | optional | optional | optional |
environmental monitoring & setup (temperature, smoke, gas & water leak detection) | OPTIONAL | OPTIONAL | OPTIONAL | OPTIONAL |
management & communications | ||||
lcd panel | yes | YES | YES | YES |
dry contact (with relay) | YES | YES | YES | YES |
EMERGENCY POWER off (epo) | YES | YES | YES | YES |
power management software | YES | YES | YES | YES |
serial port | RS232 x 1 + RS485 x 1 + Dry Contact x1 | RS232 X 1 + RS485 X 1 + DRY CONTACT X1 | RS232 X 1 + RS485 X 1 + DRY CONTACT X1 | RS232 X 1 + RS485 X 1 + DRY CONTACT X1 |
snmp/http remote monitoring | included | INCLUDED | INCLUDED | INCLUDED |
dimensions | ||||
Dimensions (WXHXD IN MM) | 755 x 1150 x 1130 | 755 X 1600 X 1130 | 755 X 1600 X 1130 | 755 X 1600 X 1130 |
wedight (kg) | 170 | 231 | 231 | 266 |
environmental | ||||
operating temperature | 0 ~ 40 | 0 ~ 40 | 0 ~ 40 | 0 ~ 40 |
OPERATING RELATIVE HUMIDITY (NON-CONDENSING) (%) | 0 ~ 95 | 0 ~ 95 | 0 ~ 95 | 0 ~ 95 |
storage RELATIVE HUMIDITY (NON-CONDENSING) (%) | 0 ~ 95 | 0 ~ 95 | 0 ~ 95 | 0 ~ 95 |
storage temperature (°C) | -40 ~ 70 | -40 ~ 70 | -40 ~ 70 | -40 ~ 70 |
audible noise at 1m from surface of unit (db) | 58 | 58 | 58 | 58 |
warranty & services | ||||
standard warranty | 2 year for electronics - 1 year for batteries | 2 YEAR FOR ELECTRONICS - 1 YEAR FOR BATTERIES | 2 YEAR FOR ELECTRONICS - 1 YEAR FOR BATTERIES | 2 YEAR FOR ELECTRONICS - 1 YEAR FOR BATTERIES |
extended warranty available | yes | YES | YES | YES |
start-up commissioning service 5x8 | included | included | included | included |
START-UP COMMISSIONING SERVICE 7X24 | optional | optional | optional | optional |
battery monitoring system | optional | optional | optional | optional |
environmental monitoring & setup (temperature, smoke, gas & water leak detection) | optional | optional | optional | optional |
certifications | ||||
certifications | CE, IEC62040-1, IEC62040-2 | CE, IEC62040-1, IEC62040-2 | CE, IEC62040-1, IEC62040-2 | CE, IEC62040-1, IEC62040-2 |
General | 120kVA/108kw | 150kVA/135kW | 200kVA/180kW | 250kVA/225kW |
---|---|---|---|---|
Power | three phase | three phase | three phase | three Phase |
energy saving technology | online eco mode efficiency up to 98% | ONLINE ECO MODE EFFICIENCY UP TO 98% | ONLINE ECO MODE EFFICIENCY UP TO 98% | ONLINE ECO MODE EFFICIENCY UP TO 98% |
normal mode efficiency (%) | 96% | 96% | 96% | 96% |
battery MODE EFFICIENCY (%) | 96% | 96% | 96% | 96% |
parallel expansion (max. units) | 4 | 4 | 4 | 4 |
input | ||||
dual power inputs | Yes | yes | yes | yes |
nominal input voltage (vac) | Line to neutral (l-n): 220, 230, 240 vac, line to line (l-L): 380, 400, 415 vac | LINE TO NEUTRAL (L-N): 220, 230, 240 VAC, LINE TO LINE (L-L): 380, 400, 415 VAC | LINE TO NEUTRAL (L-N): 220, 230, 240 VAC, LINE TO LINE (L-L): 380, 400, 415 VAC | LINE TO NEUTRAL (L-N): 220, 230, 240 VAC, LINE TO LINE (L-L): 380, 400, 415 VAC |
input voltage range (vac) | LINE TO NEUTRAL (L-N): 132 ~ 276 vac, LINE TO LINE (L-L): 228 ~ 478 VAC | LINE TO NEUTRAL (L-N): 132 ~ 276 VAC, LINE TO LINE (L-L): 228 ~ 478 VAC | LINE TO NEUTRAL (L-N): 132 ~ 276 VAC, LINE TO LINE (L-L): 228 ~ 478 VAC | LINE TO NEUTRAL (L-N): 132 ~ 276 VAC, LINE TO LINE (L-L): 228 ~ 478 VAC |
INPUT frequency (hz) | 50 ± 3, 60 ± 3 | 50 ± 3, 60 ± 3 | 50 ± 3, 60 ± 3 | 50 ± 3, 60 ± 3 |
INPUT FREQUENCY range (HZ) | 40 ~ 70 | 40 ~ 70 | 40 ~ 70 | 40 ~ 70 |
input power factor | 0.99 | 0.99 | 0.99 | 0.99 |
output | ||||
capacity (va) | 120000 | 150000 | 200000 | 250000 |
capacity (watts) | 108000 | 135000 | 180000 | 225000 |
rated output voltage (vac) | line to netural (l-N): 220, 230, 240 vac, line to line (l-L): 380, 400, 415 vac | LINE TO NETURAL (L-N): 220, 230, 240 VAC, LINE TO LINE (L-L): 380, 400, 415 VAC | LINE TO NETURAL (L-N): 220, 230, 240 VAC, LINE TO LINE (L-L): 380, 400, 415 VAC | LINE TO NETURAL (L-N): 220, 230, 240 VAC, LINE TO LINE (L-L): 380, 400, 415 VAC |
output voltage tolerance (%) | 1% | 1% | 1% | 1% |
output frequency (hz ± %) | 50 ± 0.1, 60 ± 0.1 | 50 ± 0.1, 60 ± 0.1 | 50 ± 0.1, 60 ± 0.1 | 50 ± 0.1, 60 ± 0.1 |
power factor | 0.9 | 0.9 | 0.9 | 0.9 |
overload protection (line mode) | 105~110% Load for 60 min, 110~125% Load for 10 min, 125~150% Load for 1 min, >150% Load Immediately | 105~110% LOAD FOR 60 MIN, 110~125% LOAD FOR 10 MIN, 125~150% LOAD FOR 1 MIN, >150% LOAD IMMEDIATELY | 105~110% LOAD FOR 60 MIN, 110~125% LOAD FOR 10 MIN, 125~150% LOAD FOR 1 MIN, >150% LOAD IMMEDIATELY | 105~110% LOAD FOR 60 MIN, 110~125% LOAD FOR 10 MIN, 125~150% LOAD FOR 1 MIN, >150% LOAD IMMEDIATELY |
crest factor | 3:1 | 3:1 | 3:1 | 3:1 |
harmonic distortion (linear load) | THD<1% | THD<1% | THD<1% | THD<1% |
HARMONIC DISTORTION (non-LINEAR LOAD) | THD<5.5% | THD<5.5% | THD<5.5% | THD<5.5% |
BAttery | ||||
battery type | vrla | VRLA | VRLA | VRLA |
Battery design life | 8 Year Design with UPS Solutions External Battery Cabinet | 8 YEAR DESIGN WITH UPS SOLUTIONS EXTERNAL BATTERY CABINET | 8 YEAR DESIGN WITH UPS SOLUTIONS EXTERNAL BATTERY CABINET | 8 YEAR DESIGN WITH UPS SOLUTIONS EXTERNAL BATTERY CABINET |
Internal batteries | NO | NO | NO | NO |
external battery cabinet (optional) | YES | YES | YES | YES |
Battery quantity | Configured by UPS Solutions as per required battery runtime | CONFIGURED BY UPS SOLUTIONS AS PER REQUIRED BATTERY RUNTIME | CONFIGURED BY UPS SOLUTIONS AS PER REQUIRED BATTERY RUNTIME | CONFIGURED BY UPS SOLUTIONS AS PER REQUIRED BATTERY RUNTIME |
Battery monitoring system | optional | optional | optional | optional |
environmental monitoring & setup (temperature, smoke, gas & water leak detection) | OPTIONAL | OPTIONAL | OPTIONAL | OPTIONAL |
management & communications | ||||
lcd panel | yes | YES | YES | YES |
dry contact (with relay) | YES | YES | YES | YES |
EMERGENCY POWER off (epo) | YES | YES | YES | YES |
power management software | YES | YES | YES | YES |
serial port | RS232 x 1 + RS485 x 1 + Dry Contact x1 | RS232 X 1 + RS485 X 1 + DRY CONTACT X1 | RS232 X 1 + RS485 X 1 + DRY CONTACT X1 | RS232 X 1 + RS485 X 1 + DRY CONTACT X1 |
snmp/http remote monitoring | included | INCLUDED | INCLUDED | INCLUDED |
dimensions | ||||
Dimensions (WXHXD IN MM) | 600 x 1400 x 980 | 650 x 1600 x 960 | 650 x 1600 x 960 | 650 x 2000 x 960 |
wedight (kg) | 266 | 305 | 350 | 445 |
environmental | ||||
operating temperature | 0 ~ 40 | 0 ~ 40 | 0 ~ 40 | 0 ~ 40 |
OPERATING RELATIVE HUMIDITY (NON-CONDENSING) (%) | 0 ~ 95 | 0 ~ 95 | 0 ~ 95 | 0 ~ 95 |
storage RELATIVE HUMIDITY (NON-CONDENSING) (%) | 0 ~ 95 | 0 ~ 95 | 0 ~ 95 | 0 ~ 95 |
storage temperature (°C) | -40 ~ 70 | -40 ~ 70 | -40 ~ 70 | -40 ~ 70 |
audible noise at 1m from surface of unit (db) | 58 | 58 | 58 | 58 |
warranty & services | ||||
standard warranty | 2 year for electronics - 1 year for batteries | 2 YEAR FOR ELECTRONICS - 1 YEAR FOR BATTERIES | 2 YEAR FOR ELECTRONICS - 1 YEAR FOR BATTERIES | 2 YEAR FOR ELECTRONICS - 1 YEAR FOR BATTERIES |
extended warranty available | yes | YES | YES | YES |
start-up commissioning service 5x8 | included | included | included | included |
START-UP COMMISSIONING SERVICE 7X24 | optional | optional | optional | optional |
battery monitoring system | optional | optional | optional | optional |
environmental monitoring & setup (temperature, smoke, gas & water leak detection) | optional | optional | optional | optional |
certifications | ||||
certifications | CE, IEC62040-1, IEC62040-2 | CE, IEC62040-1, IEC62040-2 | CE, IEC62040-1, IEC62040-2 | CE, IEC62040-1, IEC62040-2 |
General | 300kVA/270kw | 400kVA/360kW | 500kVA/450kW |
---|---|---|---|
Power | three phase | three phase | three phase |
energy saving technology | online eco mode efficiency up to 98% | ONLINE ECO MODE EFFICIENCY UP TO 98% | ONLINE ECO MODE EFFICIENCY UP TO 98% |
normal mode efficiency (%) | 96% | 96% | 96% |
battery MODE EFFICIENCY (%) | 96% | 96% | 96% |
parallel expansion (max. units) | 4 | 4 | 4 |
input | |||
dual power inputs | Yes | yes | yes |
nominal input voltage (vac) | Line to neutral (l-n): 220, 230, 240 vac, line to line (l-L): 380, 400, 415 vac | LINE TO NEUTRAL (L-N): 220, 230, 240 VAC, LINE TO LINE (L-L): 380, 400, 415 VAC | LINE TO NEUTRAL (L-N): 220, 230, 240 VAC, LINE TO LINE (L-L): 380, 400, 415 VAC |
input voltage range (vac) | LINE TO NEUTRAL (L-N): 132 ~ 276 vac, LINE TO LINE (L-L): 228 ~ 478 VAC | LINE TO NEUTRAL (L-N): 132 ~ 276 VAC, LINE TO LINE (L-L): 228 ~ 478 VAC | LINE TO NEUTRAL (L-N): 132 ~ 276 VAC, LINE TO LINE (L-L): 228 ~ 478 VAC |
INPUT frequency (hz) | 50 ± 3, 60 ± 3 | 50 ± 3, 60 ± 3 | 50 ± 3, 60 ± 3 |
INPUT FREQUENCY range (HZ) | 40 ~ 70 | 40 ~ 70 | 40 ~ 70 |
input power factor | 0.99 | 0.99 | 0.99 |
output | |||
capacity (va) | 300000 | 400000 | 500000 |
capacity (watts) | 270000 | 360000 | 450000 |
rated output voltage (vac) | line to netural (l-N): 220, 230, 240 vac, line to line (l-L): 380, 400, 415 vac | LINE TO NETURAL (L-N): 220, 230, 240 VAC, LINE TO LINE (L-L): 380, 400, 415 VAC | LINE TO NETURAL (L-N): 220, 230, 240 VAC, LINE TO LINE (L-L): 380, 400, 415 VAC |
output voltage tolerance (%) | 1% | 1% | 1% |
output frequency (hz ± %) | 50 ± 0.1, 60 ± 0.1 | 50 ± 0.1, 60 ± 0.1 | 50 ± 0.1, 60 ± 0.1 |
power factor | 0.9 | 0.9 | 0.9 |
overload protection (line mode) | 105~110% Load for 60 min, 110~125% Load for 10 min, 125~150% Load for 1 min, >150% Load Immediately | 105~110% LOAD FOR 60 MIN, 110~125% LOAD FOR 10 MIN, 125~150% LOAD FOR 1 MIN, >150% LOAD IMMEDIATELY | 105~110% LOAD FOR 60 MIN, 110~125% LOAD FOR 10 MIN, 125~150% LOAD FOR 1 MIN, >150% LOAD IMMEDIATELY |
crest factor | 3:1 | 3:1 | 3:1 |
harmonic distortion (linear load) | THD<1% | THD<1% | THD<1% |
HARMONIC DISTORTION (non-LINEAR LOAD) | THD<5.5% | THD<5.5% | THD<5.5% |
BAttery | |||
battery type | vrla | VRLA | VRLA |
Battery design life | 8 Year Design with UPS Solutions External Battery Cabinet | 8 YEAR DESIGN WITH UPS SOLUTIONS EXTERNAL BATTERY CABINET | 8 YEAR DESIGN WITH UPS SOLUTIONS EXTERNAL BATTERY CABINET |
Internal batteries | NO | NO | NO |
external battery cabinet (optional) | YES | YES | YES |
Battery quantity | Configured by UPS Solutions as per required battery runtime | CONFIGURED BY UPS SOLUTIONS AS PER REQUIRED BATTERY RUNTIME | CONFIGURED BY UPS SOLUTIONS AS PER REQUIRED BATTERY RUNTIME |
Battery monitoring system | optional | optional | optional |
environmental monitoring & setup (temperature, smoke, gas & water leak detection) | OPTIONAL | OPTIONAL | OPTIONAL |
management & communications | |||
lcd panel | yes | YES | YES |
dry contact (with relay) | YES | YES | YES |
EMERGENCY POWER off (epo) | YES | YES | YES |
power management software | YES | YES | YES |
serial port | RS232 x 1 + RS485 x 1 + Dry Contact x1 | RS232 X 1 + RS485 X 1 + DRY CONTACT X1 | RS232 X 1 + RS485 X 1 + DRY CONTACT X1 |
snmp/http remote monitoring | included | INCLUDED | INCLUDED |
dimensions | |||
Dimensions (WXHXD IN MM) | 600 x 2000 x 960 | 1300 x 2000 x 1100 | 1300 x 2000 x 1100 |
wedight (kg) | 490 | 810 | 900 |
environmental | |||
operating temperature | 0 ~ 40 | 0 ~ 40 | 0 ~ 40 |
OPERATING RELATIVE HUMIDITY (NON-CONDENSING) (%) | 0 ~ 95 | 0 ~ 95 | 0 ~ 95 |
storage RELATIVE HUMIDITY (NON-CONDENSING) (%) | 0 ~ 95 | 0 ~ 95 | 0 ~ 95 |
storage temperature (°C) | -40 ~ 70 | -40 ~ 70 | -40 ~ 70 |
audible noise at 1m from surface of unit (db) | 58 | 58 | 58 |
warranty & services | |||
standard warranty | 2 year for electronics - 1 year for batteries | 2 YEAR FOR ELECTRONICS - 1 YEAR FOR BATTERIES | 2 YEAR FOR ELECTRONICS - 1 YEAR FOR BATTERIES |
extended warranty available | yes | YES | YES |
start-up commissioning service 5x8 | included | included | included |
START-UP COMMISSIONING SERVICE 7X24 | optional | optional | optional |
battery monitoring system | optional | optional | optional |
environmental monitoring & setup (temperature, smoke, gas & water leak detection) | optional | optional | optional |
certifications | |||
certifications | CE, IEC62040-1, IEC62040-2 | CE, IEC62040-1, IEC62040-2 | CE, IEC62040-1, IEC62040-2 |
Contact us now!
For UPS systems there is design and engineering that will need to be done so it is best to book a site inspection or enquire directly with our team by filling out the form, emailing sales@upss.com.au or calling 1300 555 992.
1300 555 992