For urgent enquiries please call us on the line below from 8:30AM-5PM AEST, if you have a contract, we offer 24/7 support through this number.
We endeavour to respond to all contact forms within (1) hour of receipt during business hours.
We can support the following services Australia Wide:
Uninterruptible Power Supplies (UPS Systems)
Battery Banks
Replacement Batteries
Server Room Cooling
✓ True Three Level Rectifier and Inverter Technology
✓ Ultra High Energy Efficiency
✓ Full Rated Power Factor kW=kVA
• LevelUps Series with Innovative 3 Level Technology is a true on-line double conversion, three-phase UPS system that provides one of the highest level energy efficiencies in the industry.
• Three level inverter & rectifier design LevelUps Series brings the newest power conversion technology and delivers efficiency up to 96% at 50-75% load operation which is the most common operating range.
• Less energy consumption to supply the loads thanks to high
efficiency up to 96%.
• Reduced energy loss.
• Reduced electricity usage and air conditioning requirements.
• Reduction in operating cost of UPS.
• IGBT based power factor correction technology provides
input power factor close to 1 (≥ 0,99). The high input power
leads to reduced electricity pay-out, minimizes cable,
switchboard, fuse and generator requirements, thus
reducing investment cost.
• Low input current total harmonic distortion (THDi) less
than 3% helps to avoid the disturbance and expensive
harmonic filters.
• Small footprint and easy maintenance.
• Parallel configuration up to 8 units per redundancy (N+1)
and power increase.
• Loop connection helps the UPS system to continue the
operation when the connection cable is interrupted.
• Dual Input
• Common Battery
• Backfeed Protection
• Cold Start (Optional)
• Advanced Battery Management
• Short Circuit and Overload Protection
• Parallel Ready
• Redundant Power Supply
• Power Walk-in for Progressive Rectifier Start-up when the Mains is Restored.
• Battery Temperature Sensor
• Static and Manual Bypass Operation
• 500 Real Time Event Log with Detailed Parameters
• User Friendly Multilingual 320x240 Graphic Display Provides
• Operation Information
• Monitoring and Shutdown Software
• RS232 Serial and RS485 Ports
• Modbus RTU (Optional)
• 2 Communication Slots
• Remote Emergency Power Off (Optional)
• Remote Display Panel (Optional)
• Dry Contact (Optional)
• SNMP (Optional)
• ProfiBUS (Optional)
• Output power factor of 1 (kVA=kW) rate provides up to 25%
more active power than a traditional UPS.
• Suitable for modern power supply application with unit or
capacitive power factor (e.g. new servers generation).
• No reduction in active power from 0,9 leading to 0,9
lagging.
• Temperature sensor for external battery cabinets for
extended runtimes.
• External battery cabinets for different sizes of batteries to
provide extended runtimes.
• Different sizes of 10-40kVA cabinets for larger capacity of
internal batteries when long autonomy times are required.
• 3/1 Phase version is available for 10-30kVA power ratings.
• Frequency converter mode.
• Isolation transformers to vary neutral connectivity in the
event of separate power sources or for galvanic isolation
between input and output.
• Compatible version with EN 50171 for supplying power to
emergency lighting systems.
MODULES | BRIEF DESCRIPTION | DIMENSIONS (WxLxH) | PRICE EX. GST |
---|---|---|---|
MAK-LEVELUPS-10KVA | UPS Solutions Makelsan 10kVA Tower 3 Phase including 60x9Ah 12V batteries, SNMP and dry contact | 490x805x1190mm | Call for Pricing |
MAK-LEVELUPS-20KVA | UPS Solutions Makelsan 20kVA Tower 3 Phase Including 60x9Ah 12V batteries, SNMP and dry contact | 490x805x1190mm | Call for Pricing |
MAK-LEVELUPS-40KVA | UPS Solutions Makelsan 40kVA Tower 3 Phase Including 60x18Ah 12V batteries, SNMP and dry contact | 490x805x1190mm | Call for Pricing |
MAK-LEVELUPS-60KVA | UPS Solutions Makelsan 60kVA Tower 3 Phase Including 60x24Ah 12V batteries, SNMP and dry contact | 771x763x1555mm | Call for Pricing |
MAK-LEVELUPS-80KVA | UPS Solutions Makelsan 80kVA Tower 3 Phase Including 60x38Ah 12V batteries, SNMP and dry contact | 771x763x1555mm | Call for Pricing |
MAK-LEVELUPS-100KVA | UPS Solutions Makelsan 100kVA Tower 3 Phase Including 60x38Ah 12V batteries, SNMP and dry contact | 810x820x1705mm | Call for Pricing |
MAK-LEVELUPS-120KVA | UPS Solutions Makelsan 120kVA Tower 3 Phase including 60x50Ah 12V batteries, SNMP and dry contact | 810x820x1705mm | Call for Pricing |
MAK-LEVELUPS-160KVA | UPS Solutions Makelsan 160kVA Tower 3 Phase including 60x65Ah 12V batteries, SNMP and dry contact | 830x850x1800mm | Call for Pricing |
MAK-LEVELUPS-200KVA | UPS Solutions Makelsan 200kVA Tower 3 Phase Including 60x80Ah 12V batteries, SNMP and dry contact | 830x850x 800mm | Call for Pricing |
MAK-LEVELUPS-300KVA | UPS Solutions Makelsan 300kVA Tower 3 Phase including 60x 100Ah 12V batteries, SNMP and dry contact | 825x1200x2102mm | Call for Pricing |
MAK-LEVELUPS-400KVA | UPS Solutions Makelsan 400kVA Tower 3 Phase including 60x 100Ah 12V batteries, SNMP and dry contact | 825x1200x2102mm | Call For Pricing |
MAK-LEVELUPS-500KVA | UPS Solutions Makelsan 500kVA Tower 3 Phase including 60x 100Ah 12V batteries, SNMP and dry contact | 825x1200x2102mm | Call For Pricing |
MAK-LEVELUPS-600KVA | UPS Solutions Makelsan 600kVA Tower 3 Phase including 60x 100Ah 12V batteries, SNMP and dry contact | 825x2435x2003mm | Call For Pricing |
MAK-LEVELUPS-800KVA | UPS Solutions Makelsan 800kVA Tower 3 Phase including 60x 100Ah 12V batteries, SNMP and dry contact | 825x2435x2003mm | Call For Pricing |
MAK-LEVELUPS-1000KVA | UPS Solutions Makelsan 1000kVA Tower 3 Phase including 60x 100Ah 12V batteries, SNMP and dry contact | 825x2435x2003mm | Call For Pricing |
For UPS systems there is design and engineering that will need to be done so it is best to book a site inspection or enquire directly with our team by filling out the form, emailing SALES@UPSS.COM.AU or calling 1300 555 992.