EATON 93PM
30KVA - 200KVA

✓ Industry-leading 96.7% Efficiency

✓ On-line Double Conversion

✓ 3 Phase Power Protection

EATON 93PM
30KVA - 200KVA

The new Eaton 93PM, featuring industry-leading operating efficiency of 96.7% and world-class intelligent software solutions, the 93PM is the surest way to secure the continuity of your mission-critical applications. All this compactly in 0.5 m2.

On-line double conversion topology ensures the UPS output is not affected by any abnormalities in the utility power and keeps critical load equipment protected against all common power problems. With Eaton 93PM UPS, modern multi-level converter technology ensures that in double conversion no energy is wasted and the UPS operating efficiency is top- of-market 96.7% resulting in significant savings in operational costs.
Eaton's advanced charging algorithm prolongs battery service life significantly compared to traditional charging methods. Automatic battery tests ensure any defects on batteries are detected and any failed blocks replaced on time. 

FEATURES & BENEFITS

 96.7% efficiency in double conversion
• > 99% efficiency with Energy Saver System (ESS)
• Standard 10-20 minutes full load runtime with internal batteries
• Intelligent Power Manager allows you to monitor and manage your UPS system as an integral part of power infrastructure
• Plugs into leading virtualisation management systems like VMware vCenter, Microsoft SCVMM and Citrix XenCenter
• Display shows power quality, energy consumption and efficiency trends
• Data logging feature allows easy measurement, monitoring and managing. 

EATON 93PM
30KVA - 200KVA

93PM 30kW/8mins UPS, 50kW frame with 108x34W, internal MBS 93PM30(50)N8-MBS
93PM 30kW/8mins UPS, 50kW frame with 108x34W, internal MBS 93PM30(50)N8-MBS
93PM 30kW/8mins UPS, 50kW frame with 108x34W, internal MBS 93PM30(50)N8-MBS
93PM 30kW/8mins UPS, 50kW frame with 108x34W, internal MBS 93PM30(50)N8-MBS
93PM 30kW/8mins UPS, 50kW frame with 108x34W, internal MBS 93PM30(50)N8-MBS

93PM 30kW/8mins UPS, 50kW frame with 108x34W, internal MBS 93PM30(50)N8-MBS

30kVA/30kW

Input: Hardwired Output: Hardwired
Batteries: Lead Acid
Communication Management: Input / Output dry contacts, Optional RS232 serial port (USB and RS232 serial ports cannot be used simultaneously) 1 mini terminal block for remote ON/OFF and emergency stop, SNMP card or NMC ModBus/JBus or MC Contacts/Serial
Warranty: 1 years warranty, Standard product exchange, including the battery
UPS Topology: Online Double Conversion
Runtime: Extended Runtime
Form Factor: Tower
Wiring Type: Three Phase Input / Output
Size: 560 x 914 x 1876 (mm) Weight: 596 kg
Part Number: 93PM30(50)N8-MBS

POA

View Details
93PM 40kW/7mins UPS, 50kW frame with 144x34W, internal MBS 93PM40(50)N7-MBS
93PM 40kW/7mins UPS, 50kW frame with 144x34W, internal MBS 93PM40(50)N7-MBS
93PM 40kW/7mins UPS, 50kW frame with 144x34W, internal MBS 93PM40(50)N7-MBS
93PM 40kW/7mins UPS, 50kW frame with 144x34W, internal MBS 93PM40(50)N7-MBS
93PM 40kW/7mins UPS, 50kW frame with 144x34W, internal MBS 93PM40(50)N7-MBS

93PM 40kW/7mins UPS, 50kW frame with 144x34W, internal MBS 93PM40(50)N7-MBS

40kVA/40kW

Input: Hardwired Output: Hardwired
Batteries: Lead Acid
Communication Management: Input / Output dry contacts, Optional RS232 serial port (USB and RS232 serial ports cannot be used simultaneously) 1 mini terminal block for remote ON/OFF and emergency stop, SNMP card or NMC ModBus/JBus or MC Contacts/Serial
Warranty: 1 years warranty, Standard product exchange, including the battery
UPS Topology: Online Double Conversion
Runtime: Extended Runtime
Form Factor: Tower
Wiring Type: Three Phase Input / Output
Size: 560 x 914 x 1876 (mm) Weight: 694 kg
Part Number: 93PM40(50)N7-MBS

POA

View Details
93PM 50kW/7mins UPS, 50kW frame with 180x34W, internal MBS 93PM50(50)N7-MBS
93PM 50kW/7mins UPS, 50kW frame with 180x34W, internal MBS 93PM50(50)N7-MBS
93PM 50kW/7mins UPS, 50kW frame with 180x34W, internal MBS 93PM50(50)N7-MBS
93PM 50kW/7mins UPS, 50kW frame with 180x34W, internal MBS 93PM50(50)N7-MBS
93PM 50kW/7mins UPS, 50kW frame with 180x34W, internal MBS 93PM50(50)N7-MBS

93PM 50kW/7mins UPS, 50kW frame with 180x34W, internal MBS 93PM50(50)N7-MBS

50kVA/50kW

Input: Hardwired Output: Hardwired
Batteries: Lead Acid
Communication Management: Input / Output dry contacts, Optional RS232 serial port (USB and RS232 serial ports cannot be used simultaneously) 1 mini terminal block for remote ON/OFF and emergency stop, SNMP card or NMC ModBus/JBus or MC Contacts/Serial
Warranty: 1 years warranty, Standard product exchange, including the battery
UPS Topology: Online Double Conversion
Runtime: Extended Runtime
Form Factor: Tower
Wiring Type: Three Phase Input / Output
Size: 560 x 914 x 1876 (mm) Weight: 792 kg
Part Number: 93PM50(50)N7-MBS

POA

View Details
93PM 80KW Upgradable to 100KW (No internal batteries) 93PM80(100)
93PM 80KW Upgradable to 100KW (No internal batteries) 93PM80(100)
93PM 80KW Upgradable to 100KW (No internal batteries) 93PM80(100)
93PM 80KW Upgradable to 100KW (No internal batteries) 93PM80(100)
93PM 80KW Upgradable to 100KW (No internal batteries) 93PM80(100)

93PM 80KW Upgradable to 100KW (No internal batteries) 93PM80(100)

80kVA/80kW

Input: Hardwired Output: Hardwired
Batteries: Lead Acid
Communication Management: Input / Output dry contacts, Optional RS232 serial port (USB and RS232 serial ports cannot be used simultaneously) 1 mini terminal block for remote ON/OFF and emergency stop, SNMP card or NMC ModBus/JBus or MC Contacts/Serial
Warranty: 1 years warranty, Standard product exchange, including the battery
UPS Topology: Online Double Conversion
Runtime: Extended Runtime
Form Factor: Tower
Wiring Type: Three Phase Input / Output
Size: 560 x 914 x 1876 (mm) Weight: 338 kg
Part Number: 93PM80(100)

POA

View Details
93PM 100kW system (No internal batteries) 93PM100(100)-MBS
93PM 100kW system (No internal batteries) 93PM100(100)-MBS
93PM 100kW system (No internal batteries) 93PM100(100)-MBS
93PM 100kW system (No internal batteries) 93PM100(100)-MBS
93PM 100kW system (No internal batteries) 93PM100(100)-MBS

93PM 100kW system (No internal batteries) 93PM100(100)-MBS

100kVA/100kW

2 UPM, with Input switch, MBS & Battery Breaker

Input: Hardwired Output: Hardwired
Batteries: Lead Acid
Communication Management: Input / Output dry contacts, Optional RS232 serial port (USB and RS232 serial ports cannot be used simultaneously) 1 mini terminal block for remote ON/OFF and emergency stop, SNMP card or NMC ModBus/JBus or MC Contacts/Serial
Warranty: 1 years warranty, Standard product exchange, including the battery
UPS Topology: Online Double Conversion
Runtime: Extended Runtime
Form Factor: Tower
Wiring Type: Three Phase Input / Output
Size: 560 x 914 x 1876 (mm) Weight: 338 kg
Part Number: 93PM100(100)-MBS

POA

View Details
93PM 160KW UPS Upgradable to 200KW (No internal batteries) 93PM160(200)
93PM 160KW UPS Upgradable to 200KW (No internal batteries) 93PM160(200)
93PM 160KW UPS Upgradable to 200KW (No internal batteries) 93PM160(200)
93PM 160KW UPS Upgradable to 200KW (No internal batteries) 93PM160(200)
93PM 160KW UPS Upgradable to 200KW (No internal batteries) 93PM160(200)

93PM 160KW UPS Upgradable to 200KW (No internal batteries) 93PM160(200)

200kVA/200kW

Input: Hardwired Output: Hardwired
Batteries: Lead Acid
Communication Management: Input / Output dry contacts, Optional RS232 serial port (USB and RS232 serial ports cannot be used simultaneously) 1 mini terminal block for remote ON/OFF and emergency stop, SNMP card or NMC ModBus/JBus or MC Contacts/Serial
Warranty: 1 years warranty, Standard product exchange, including the battery
UPS Topology: Online Double Conversion
Runtime: Extended Runtime
Form Factor: Tower
Wiring Type: Three Phase Input / Output
Size: 760 x 914 x 1876 (mm) Weight: 556 kg
Part Number: 93PM160(200)

POA

View Details
93PM 200KW UPS  (No internal batteries) 93PM200(200)
93PM 200KW UPS  (No internal batteries) 93PM200(200)
93PM 200KW UPS  (No internal batteries) 93PM200(200)
93PM 200KW UPS  (No internal batteries) 93PM200(200)
93PM 200KW UPS  (No internal batteries) 93PM200(200)

93PM 200KW UPS (No internal batteries) 93PM200(200)

200kVA/200kW

Input: Hardwired Output: Hardwired
Batteries: Lead Acid
Communication Management: Input / Output dry contacts, Optional RS232 serial port (USB and RS232 serial ports cannot be used simultaneously) 1 mini terminal block for remote ON/OFF and emergency stop, SNMP card or NMC ModBus/JBus or MC Contacts/Serial
Warranty: 1 years warranty, Standard product exchange, including the battery
UPS Topology: Online Double Conversion
Runtime: Extended Runtime
Form Factor: Tower
Wiring Type: Three Phase Input / Output
Size: 760 x 914 x 1876 (mm) Weight: 556 kg
Part Number: 93PM200(200)